Insulation: R-Values, and the Table Number That Moved

Prescriptive minimums by climate zone, plus the edition trap that sends people to the wrong table entirely.
2021 IECC minimums (ceiling / wood-frame wall / floor)
| Zone 0-1 | R-30 / R-13 / R-13 |
| Zone 2 | R-49 / R-13 / R-13 |
| Zone 3 | R-49 / R-20 or 13+5ci / R-19 |
| Zone 4 except Marine | R-60 / R-30 or 20+5ci / R-19 |
| Zone 5 and Marine 4 | R-60 / R-30 or 20+5ci / R-30 |
| Zone 6 | R-60 / R-30 or 20+5ci / R-30 |
| Zone 7-8 | R-60 / R-30 or 20+5ci / R-38 |
Reading the notation
| 13+5ci | R-13 in the cavity PLUS R-5 continuous over the framing |
| ci | Continuous insulation, unbroken by studs |
| Why both are offered | They are ALTERNATIVES. A cavity-only option usually exists alongside the continuous one, so check both before paying for exterior board you may not need. |
The trap: the table number changed between editions
- In the 2021 IECC the R-values are in TABLE R402.1.3, and R402.1.2 holds the U-factor criteria.
- In the 2018 IECC it is the other way round: TABLE R402.1.2 is the R-value table.
- So looking up 'R402.1.3' in a 2018-adopting state lands you on U-factors and you will read them as R-values. The citation is right and the SCOPE is wrong, which is the hardest kind of error to spot.
- Check which EDITION your jurisdiction adopted before you check which table.